| Nominal wattage | 250.00 W |
| Nominal output power | 250 W 1) |
| Nominal voltage | 220…240 V |
| Nominal output voltage | 24 V 2) |
| Input voltage range | 198…264 V |
| Input voltage AC | 198…264 V 3) |
| U-OUT (working voltage) | 24 V |
| Type of current | AC |
| Nominal current | 1500 mA |
| Nominal output current | 0…8330 mA |
| Inrush current | 46.2 A |
| Output current tolerance | +/- 5 % |
| Output ripple current (120 Hz) | +/- 1.0 % |
| Mains frequency | 50…60 Hz |
| Total harmonic distortion | < 10 % 4) |
| Power factor λ | ≥0.95 5) |
| ECG efficiency | 93 % 6) |
| Device power loss | 18.8 W 7) |
| Max. ECG no. on circuit breaker 10 A (B) | 2 |
| Max. ECG no. on circuit breaker 16 A (B) | 5 |
| Max. ECG no. on circuit breaker 25 A (B) | 7 |
| Max. ECG no. on circuit breaker 32 A (B) | 10 |
| Max. ECG no. on circuit breaker 10 A (C) | 5 |
| Max. ECG no. on circuit breaker 16 A (C) | 8 |
| Max. ECG no. on circuit breaker 32 A (C) | 16 |
| Surge capability (L/N-Ground) | 2 kV |
| Surge capability (L-N) | 1 kV |
| Galvanic isolation | SELV |
| Operating frequency | 50/60 Hz |
| Power loss in stand-by mode | ≤0.5 W |
| Length | 346.00 mm |
| Mounting hole spacing, length | 336 mm |
| Width | 45.00 mm |
| Height | 32.00 mm |
| Cable cross-section, input side | 0.5…1.5 mm² |
| Cable cross-section, output side | 0.5…1.5 mm² |
| Prewired | No |
| Wire preparation length, input side | 7…9 mm |
| Wire preparation length, output side | 7…9 mm |
| Product weight | 610.00 g |
| Product color | White |
| Casing material | Plastic |
| Body material | Plastic |
| Ambient temperature range | -20…+80 °C |
| Maximum temperature at tc test point | 85 °C |
| Max.housing temperature in case of fault | 90 °C |
| Temperature range in operation | -20…+45 °C |
| Permitted rel. humidity during operation | 20…90 % |
| ECG lifetime | 50000 h 1) |
| Number of switching cycles | 25000 |
| Encapsulated | Yes |
| Product remark | Available from December 2025 |
| Dimmable | No |
| Overheating protection | Yes |
| Overload protection | Yes |
| Short-circuit protection | Yes |
| No-load proof | Yes |
| Max. cable length to lamp/LED module | 0,8 m |
| Suitable for fixtures with prot. class | II |
| Suitable for emergency lighting | No |
| Type of connection, output side | Screwless terminal |
| Approval marks – approval | CE, UKCA, EAC |
| Standards | Acc. to EN 61347-1, Acc. to EN 61347-2-13, Acc. to EN 55015, Acc. to EN 61547, Acc. to EN 61000-3-2, Acc. to EN 62384 |
| Protection class | II |
| Type of protection | IP20 |
| Temperature range at storage | -20…+85 °C |
| Minimum rate of recycled material in packaging | 80 % 1) |
| Minimum percentage of recycled content in the product | 0 % 1) |
| Product recyclability | Mostly recyclable product 1) |
| Packaging recyclability | Mostly recyclable packaging 1) |
| List of dangerous substances contained in the product in concentrations greater than 0.1% in mass percentage | No |
| Contains substances of very high concern in concentrations greater than 0.1% by mass percentage | Yes |
| List of substances of very high concern in concentrations greater than 0.1% in mass percentage | Lead (7439-92-1) |
| Product code | Packaging unit (Pieces/Unit) | Dimensions (length x width x height) | Gross weight | Volume |
|---|---|---|---|---|
| 4099854685958 | Folding box 1 |
51 mm x 355 mm x 38 mm | 620.00 g | 0.69 dm³ |
| 4099854685965 | Shipping box 20 |
366 mm x 275 mm x 180 mm | 12650.00 g | 18.12 dm³ |
| EAN | STK number | EFO number | UK Org |
|---|---|---|---|
| 4099854685958 | 4031502 | 6660225 | 438615902 |